Products
-
- COVID 19 Provention
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Laminar Flow Cabinet
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- X-ray Series
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
Digital Radiography and Digital Fluoroscopy System
I. Application
Full support perspective, gastrointestinal spot film, GI (barium meal, barium enema), orthopedic photography, pediatrics photography, chest, urinary system angiography, peripheral angiography operations, gynecological Photography (HSG) and many other checks, the real machine can realize all these function.
II. Standard configure
1 |
X ray Tube |
E7252X |
1Unti |
Toshiba |
2 |
Electrical Collimator |
XSQ20 |
1Unit |
|
3 |
Generator |
FSQ60 |
1Unit |
|
4 |
Flat Panel Detector |
1417V |
1Unit |
|
5 |
Diagnostic table |
ZDC20 |
1Unit |
|
6 |
Console |
KZT40 |
1Unit |
|
7 |
Intensifier |
E5830SD-P6A |
1Unit |
Toshiba |
8 |
Image acquisition workstation |
DSI60 |
1Unit |
|
9 |
Dedicated camera |
acA1920-40gm |
1Set |
BASLER |
III. Specification
Item |
Content |
Technical Parameters |
Power Supply |
Voltage |
380V±38V |
Frequency |
50Hz±1Hz |
|
Capacity |
≥65kVA |
|
Internal Resistance |
≤0.17Ω |
|
Generator (FSQ60) |
Power |
56KW |
Inverter Frequency |
440 KHz |
|
Radiography Tube voltage |
40kV~150kV step adjustment |
|
Radiography Tube current |
10mA~710mA step adjustment |
|
Radiography Time |
1.0ms~10000ms step adjustment |
|
Radiography mAs |
0.1 mAs~900 mAs |
|
Fluoroscopy Tube voltage |
40kV~125kV step adjustment |
|
Fluoroscopy Tube current |
0.5mA~10mA continuous fluoroscopy |
|
5mA~20mA Pulse fluoroscopy |
||
X-ray tube assembly (E7252X) |
Target |
Molybdenum-based lanthanum-tungsten composite |
Target angle |
12° |
|
Nominal tube voltage |
150kV |
|
Tube Focus: big/small |
1.2mm / 0.6mm |
|
Input power |
Big Focus/ 75kW Small focus/ 27kW |
|
Anode thermal capacity |
210kJ(300KHU) |
|
Anode maximum heat dissipation |
475W(667KHU/min) |
|
Component heat capacity |
900kJ(1250KHU) |
|
Anode Rotation Speed |
9700rpm |
|
|
Collimator field of view light |
Halogen lamp, AC24V/100W |
Collimator |
Visible light illumination |
Average illumination brightness: >100Lux |
|
Light field exposure time |
5-45s, 5s per step |
Diagnostic |
Table transverse movement |
220mm |
table diagnostic table |
distance |
|
SID |
1100mm~1500mm |
|
Table panel equivalent filtration |
≤1.2mmAl |
|
Point device movement range |
720mm |
|
Table height from the ground |
900mm |
|
Table size |
2100mm×796mm |
|
Table rotation |
+90°~0°~ -25° |
|
Minimum distance of the compressor from the table surface |
≤150mm |
|
Compressor pressure |
80N~130N |
|
Table bearing |
135kg |
|
Fragmentation |
Whole film, two-piece, four-slice |
|
Fixed grid |
Grid density: 103L/INCH, Ratio: 10:1, convergence distance 130 cm stationary type :15” ×18” |
|
|
Field of view size |
230mm |
Intensifier (E5830SD- P6A) |
Resolution |
52 Lp/cm |
Conversion factor |
cd / m2
SHAPE \* MERGEFORMAT 26 uGy / s |
|
X-ray camera (acA1920- 40gm) |
Signal to noise ratio |
45 dB |
Cell size |
5.86×5.86μm |
|
Number of valid pixels |
1920×1200 |
|
Wi-Fi Flat Panel Detector (1417V) |
Image Sensor |
Amorphous silicon thin film transistor |
Pixel size |
150μm |
|
Effective pixel size |
2304(H)*2800(V) |
|
Effective area(H x V) |
343(H)*416(V) |
|
Image transmission |
IEEE802.11a/b/g/n |
|
Gray scale |
14bit |
|
Spatial resolution |
3.4 Lp/mm(CsI) |
|
Energy range |
40kV -150kVP |
|
Power input |
DC24V |
|
|
|
|
|
|
1, computer: B150 PLUS motherboard; |
Image |
|
processor: Intel Core I5 6400 |
acquisition |
|
Memory: 8 GB DDR3 |
workstation |
Computer system |
Hard disk: 1T SATA (7200 rpm) |
(DSI60) |
|
Optical drive: DVR-221CHV CD burner |
|
|
NIC: Intel(R)gigabit CT |
|
|
Graphics card: gtx1050 |
|
Monitor |
Dell (DELL) U2412Mc display |
|
Workstation software |
Basic functions: new patient; new check; anonymous registration; WorkList search and advanced search; WorkList refresh; WorkList information import; check list; view image; film print; The collection part is divided into gastrointestinal collection and DR collection functions: Gastrointestinal collection function: bed selection; patient shape selection; specific examination protocol selection; gastrointestinal and contrast protocol selection; selected protocol list; real-time image noise reduction selection; real-time image enhancement selection; single frame storage; continuous perspective storage; Frame exposure storage; sequence exposure storage; real-time image horizontal flipping; real-time image vertical flipping; generator perspective state switching; perspective time accumulation; fluoroscopy time clearing; ABS function switch; DR acquisition function: window width window position adjustment; 90° rotation to the left; 90° rotation to the right; horizontal mirroring; vertical mirroring; image negative; cropping frame; exposure parameter setting; stadium focus switching; exposure mode selection; ionization chamber selection ; exposure actual dose value; system status indicator. Image viewing function: image zooming; partial zooming; original size; recovery window size; image grid display; 90° left rotation; 90° rotation to the right; horizontal mirroring; vertical mirroring; text logo; line logo; angle logo; Marking; cropping frame; rectangle marking; circle marking; polygon marking; length correction; four-corner information display; ruler display; window width window level adjustment; sequence image playback; image output; silhouette function; deleting image; image enhancement; ; image negative. Film printing function: add image; insert image; delete image; clear image; image layout; image selection; print format; film print setting; film format setting; add, modify, delete printer settings. |
IV. Work station
Integrated combined operation handle, can easily control the bed body, image system and the movement of rotary pedal, spot film;
1) The table body can +90 degrees to 0 to -25 degrees rotate.
2) Humanized design of diagnosis bedside switch operation, can control the table body and imaging system movement,so that the close table inspection is convenient and easy operation;
3) Spot film device and imaging system movement range more than 720 mm,
4) Adopts the operation of the machine move, but the patient don't need move ,, can easily finish from the throat, esophagus to the lower abdomen of a series of inspections; 5)Cassette trolley can test cassette size by itself, a key can completely finish the insert piece, save space, convenient and fast;