Products
-
- COVID 19 Provention
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Laminar Flow Cabinet
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- X-ray Series
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
Features
1. Portable delicate design, big color display, very easy to operate
2. Accurate pulse pace identification and excellent automatic analysis function
3. High accuracy digital filter, auto baseline adjustment
4. 12 leads synchronously acquisition and display
5. Working modes: Manual / Auto / Analysis/Storage
6. 800×480 graphic 7 inch color LCD screen
7. 40 patient cases save and replay
8. Adapt to 110-230V, 50/60Hz power supply
9. Built-in rechargeable Li-ion battery supports continuous work for about 4 hours.
10. 112mm*20m high resolution thermal printing
11. 300mm*230mm*75mm, 2.8kgs
12. Language: English, Chinese, French, Italian, Spanish, Russian
Technical Specifications
PARAMETER |
SPECIFICATION |
Lead |
Standard 12 leads |
Lead acquisition |
12bit/1000Hz(synchronously 12 leads) |
Work mode |
MAN, AUTO, ANALYSIS Modes |
Filter |
AC Filter : 50Hz / 60Hz EMG Filter : 25Hz / 45Hz Anti-Drift Filter : 0.15Hz (Adaptive) |
CMMR |
≥100dB (with AC FILTER) |
Input circuit |
Floating; Protection circuit against Defibrillator effect |
Input Impedance |
≥50MΩ |
Input circuit current |
≤0.05μA |
Patient current leakage |
<10μA |
Calibrating voltage |
1mV±2% |
Voltage tolerance |
≥±500mV |
Time constant |
≥3.2s |
Frequency response |
0.05~160Hz(-3db) |
Noise level |
<15μVp-p |
Inter-channel Interference |
≤0.5mm |
Sensitivity |
5,10,20, 40, Auto (mm/mV) |
Recording mode |
3ch, 3ch+, 3ch+++, 6ch Default Man. Mode is 3ch format Default Auto. Mode is 6ch+ format |
Paper speed |
6.25、12.5、25、50mm/s(±3%) |
Paper |
112mm *20m Roll paper |
Communication |
RS232/ USB port |
Power Supply |
AC 110-230V( ±10%),50/60Hz ( ±1Hz),60VA DC Built-in rechargeable battery,14.4V(2000mmAh) |
Dimension/Weight |
300mm×230mm×72mm/2.8Kg |