Products
-
- COVID 19 Provention
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Laminar Flow Cabinet
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- X-ray Series
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
This machine is used to photograph patient's chest, stomach, lumbar and extremity.
I. Features
1.It is installed with close-table graphical colorful LCD touch screen, wireless remote-control exposure, make the operator easy to use.
2.We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality, while the skin dose is low, to protect the patient better.
3.Adopt the technology of kV and mAs numeral Closed loop control, Real-time control of the microprocessor, which ensure the accuracy and repeatability of the output dose.
4.Be equipped with radiography parameter of multi-part, multi-posture, multi-body type’s adult, child physical characteristic, the operator can modify and save the parameter by himself, which make the operation more conveniently.
5.Possess multiple automatic protection and fault clue function, make the operation more safe and reliable.
6.The radiography table can float in any direction, electromagnetic braking, position the patient more convenience and accuracy.
7.X-ray generator component can move round the axis of X-ray generator, crossarm and Pillar stand, be convenient with side and slanting direction projection and radiography of patient on the stretcher.
8.Be equipped with the bucky stand, which is used in the radiography of the head, chest, belly, pelvic cavity, backbone and periphery.
9.Control console of graphic program-controlled LCD touch screen is optional, which can set the radiography parameter and exposure in another room.
II. Specification
Item |
content |
Power Output |
25KW |
Inverter Frequency  |
40KHz |
X-ray Tube  |
Rotary anode, Dual-focus, Large focus: 1.3mm*1.3mm, |
The speed of the rotary anode |
3000rpm |
Tube Current |
200mA |
Tube Voltage  |
40-125kV |
mAs |
0.4-360mAs |
Table radiography |
Grid density:103L/INCH;Grid ratio:8:1;Focusing distance:120cm;Stationary type:15"×18"(import) |
Bucky stand radiography |
Grid density:103L/INCH;Grid ratio:10:1;Focusing distance:150cm;Stationary type:18"×18"(import) |
Power Supply |
380V 50Hz, Capacity: ≥30KVA |
Operation Method |
-close-table graphic program controlled LCD touch screen operation; -20 meters wireless remote control exposure |
III. Basic Configuration
1, Novel integrative planigraphy couch 1 unit
2, Compact high-frequency and high-voltage X-ray generator 1 unit
3, Coloured LCD touch screen control box 1 unit
4, Bucky stand (with the South Korean Rulers filter line devices ) 1 unit (Optional)
IV. Structural performance
Size of the tabel |
2000×760mm |
Height of the table |
≤700mm |
Transverse travel of table |
±110mm (Electromagnetic brake ) |
Longitudinal travel of table |
±325mm(Electromagnetic brake ) |
Movement of the Grids cassette holder |
≥560mm( Cassette frame which can linkage with column to take face film; not linkage with the column , to take angle film.) |
X-ray tube assembly center rotation |
±90°(Electromagnetic brake ) |
Rotation of the pillar |
360° ( 4×90° , Mechanical brake ) |
Axial rotation |
0-35°( Mechanical brake ) |
SID |
420-1200mm(Electromagnetic brake ) |
Pillar moving along the table |
≥1350mm(Electromagnetic brake ) |
Limited time of analog light beam opening |
Approx 30s |
Size of the film |
5"×7"-14"×17"(Table radiography) |
Size of the film |
5"×7"-17"×17"(Bucky stand radiography) |
Fluctuate Move Range of Chest X-ray frame |
560-1625mm |