AR-160A High Frequency X-ray Radiography System-Radiography X-ray System,Quality Medical Equipment China-ARI Medical Equipment of High Quality - ARI Medical Technology Co., Ltd. - ARI Group

Products

AR-160A

High Frequency X-ray Radiography System


This machine is used to photograph patient's chest, stomach, lumbar and extremity.

I. Features

1.It is installed with close-table graphical colorful LCD touch screen, wireless remote-control exposure, make the operator easy to use.

2.We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality, while the skin dose is low, to protect the patient better.

3.Adopt the technology of kV and mAs numeral Closed loop control, Real-time control of the microprocessor, which ensure the accuracy and repeatability of the output dose.

4.Be equipped with radiography parameter of multi-part, multi-posture, multi-body type’s adult, child physical characteristic, the operator can modify and save the parameter by himself, which make the operation more conveniently.

5.Possess multiple automatic protection and fault clue function, make the operation more safe and reliable.

6.The radiography table can float in any direction, electromagnetic braking, position the patient more convenience and accuracy.

7.X-ray generator component can move round the axis of X-ray generator, crossarm and Pillar stand, be convenient with side and slanting direction projection and radiography of patient on the stretcher.

8.Be equipped with the bucky stand, which is used in the radiography of the head, chest, belly, pelvic cavity, backbone and periphery.

9.Control console of graphic program-controlled LCD touch screen is optional, which can set the radiography parameter and exposure in another room.

II. Specification

Item

content

Power Output

25KW

Inverter Frequency 

40KHz

X-ray Tube 

Rotary anode, Dual-focus, Large focus: 1.3mm*1.3mm,
Small focus: 0.6 mm*0.6mm, Thermal capacity:900kJ

The speed of the rotary anode

3000rpm

Tube Current

200mA

Tube Voltage 

40-125kV

mAs

0.4-360mAs

Table radiography

Grid density:103L/INCH;Grid ratio:8:1;Focusing distance:120cm;Stationary type:15"×18"(import)

Bucky stand radiography

Grid density:103L/INCH;Grid ratio:10:1;Focusing distance:150cm;Stationary type:18"×18"(import)

Power Supply

380V  50Hz, Capacity: ≥30KVA

Operation Method

-close-table graphic program controlled LCD touch screen operation;

-20 meters wireless remote control exposure

III. Basic Configuration

1, Novel integrative planigraphy couch                                        1 unit

2, Compact high-frequency and high-voltage X-ray generator                    1 unit

3, Coloured LCD touch screen control box                                     1 unit    

4, Bucky stand (with the South Korean Rulers filter line devices )                 1 unit (Optional)

IV. Structural performance 

Size of the tabel

2000×760mm

Height of the table

 â‰¤700mm

Transverse travel of table

±110mm (Electromagnetic brake )

Longitudinal travel of table  

±325mm(Electromagnetic brake )

Movement of the Grids cassette holder

≥560mm(  Cassette frame which can linkage with column to take face film; not linkage with the column , to take angle film.)

X-ray tube assembly center rotation

±90°(Electromagnetic brake )

Rotation of the pillar

360° ( 4×90° , Mechanical brake )

Axial rotation

0-35°( Mechanical brake )

SID

420-1200mm(Electromagnetic brake )

Pillar moving along the table

≥1350mm(Electromagnetic brake )

Limited time of analog light beam opening

Approx 30s

Size of the film

5"×7"-14"×17"(Table radiography)

Size of the film

5"×7"-17"×17"(Bucky stand radiography)

Fluctuate Move Range of Chest X-ray frame

560-1625mm


Copyright © 2001-2020 ARI Medical Technology Co., Ltd. - ARI Technology Group Co., Ltd. All Rights Reserved.